Set target tem for hotend to 250C
This commit is contained in:
15
macros/Calibration/PID Tuning/PID Tune Hot End 250
Normal file
15
macros/Calibration/PID Tuning/PID Tune Hot End 250
Normal file
@@ -0,0 +1,15 @@
|
||||
; 0:/macros/PID Tuning/PID Tune Hot End 250
|
||||
; Based on https://duet3d.dozuki.com/Wiki/Tuning_the_heater_temperature_control
|
||||
;
|
||||
|
||||
M291 S3 R"PID Tuning Hotend to 250c" P"Do not interrupt or leave unattended while tuning in progress."
|
||||
|
||||
M106 P0 S0.5 ; set part fan to 50%
|
||||
M303 H1 S250 ; auto tune heater 1, default PWM, 250C target or maximum temperature
|
||||
|
||||
M98 P"0:/macros/Musical Tunes/TwoBits.g"
|
||||
|
||||
M291 S3 R"PID Tuning Complete" P"Check console for heater values. Values saved to config-Override.g"
|
||||
|
||||
M307 H1 ; report values for heater 1
|
||||
M500 ; Save values to config-override.g
|
||||
Reference in New Issue
Block a user