From 7f3e5351603259df0891ace4cde2bf69c41705dd Mon Sep 17 00:00:00 2001 From: pedro Date: Sun, 2 Apr 2023 21:22:17 +0100 Subject: [PATCH] Move Accelleromenter config to the end of the config file The accelormeter is not always connected thus and error is produced, I prefer to have the error after all configs are loaded. --- config.g | 16 +++++++++------- 1 file changed, 9 insertions(+), 7 deletions(-) diff --git a/config.g b/config.g index 1c6896b..5d892e9 100644 --- a/config.g +++ b/config.g @@ -74,6 +74,14 @@ G10 P0 R0 S0 ; set initial tool 0 active a ; Filament sensor - Duet3D laser filament monitor M591 D0 P5 C"io3.in" R30:125 E5.0 S1 ; Duet3D laser sensor for extruder drive 0, connected to endstop input 4 (E0), tolerance 30 to 125%, 5mm comparison length, enabled filament monitoring +; Miscellaneous +M575 P1 S1 B57600 ; enable support for PanelDue +M501 ; load saved parameters from non-volatile memory +M911 S10 R11 P"M913 X0 Y0 G91 M83 G1 Z3 E-5 F1000" ; set tension thresholds and actions to run on power loss +M404 N1.75 D0.4 ; Filament width and nozzle diameter +;M572 D0 S0.10 ; Pressure Advance +T0 ; Define default tool + ; Accelerometer - LIS3HD ;; More info: https://duet3d.dozuki.com/Wiki/Accelerometers ;; More info: regarding sensor orientation: https://www.dropbox.com/s/hu2w5mk57l4zqpg/Accelerometer%20Orientation.pdf @@ -83,10 +91,4 @@ M593 P"ei3" F38 ; use P "shaper" input shaping to cancel ringing at center ;M593 P"none" ; disable input shaping ;M593 P"custom" H0.4:0.7 T0.0135:0.0135 ; use custom input shaping -; Miscellaneous -M575 P1 S1 B57600 ; enable support for PanelDue -M501 ; load saved parameters from non-volatile memory -M911 S10 R11 P"M913 X0 Y0 G91 M83 G1 Z3 E-5 F1000" ; set tension thresholds and actions to run on power loss -M404 N1.75 D0.4 ; Filament width and nozzle diameter -;M572 D0 S0.10 ; Pressure Advance -T0 ; Define default tool +