From 812f24d1cd54325d215ff5d37a125ebe742afc4c Mon Sep 17 00:00:00 2001 From: pedro Date: Sun, 6 Jun 2021 12:21:38 +0100 Subject: [PATCH] Tune Z probre, add warning to conf, set layer frequency --- config.g | 11 ++++++----- 1 file changed, 6 insertions(+), 5 deletions(-) diff --git a/config.g b/config.g index 418f2e2..529020a 100644 --- a/config.g +++ b/config.g @@ -37,8 +37,11 @@ M574 Y1 S1 P"io1.in" ; configure active-high endst ; Z-Probe M950 S0 C"io7.out" ; create servo pin 0 for BLTouch M558 P9 C"^io7.in" H3 F500 T12000 ; set Z probe type to bltouch and the dive height + speeds -G31 P500 X-28 Y13 Z0.9 ; set Z probe trigger value, offset and trigger height - +;; Pay special attention to the values bellow on G31, the Z value needs to be validated for your printer +;; Start with something like 0.5 +;; Documentation available: https://duet3d.dozuki.com/Wiki/Test_and_calibrate_the_Z_probe +G31 P500 X-28 Y13 Z2.235 ; set Z probe trigger value, offset and trigger height +;; M671 X-4.5:250:504.5 Y504.52:-5:504.52 S5 ; define positions of Z leadscrews or bed levelling screws M557 X25:475 Y25:475 P5 ; define 5x5 mesh grid @@ -49,19 +52,17 @@ M950 H0 C"out1" T0 ; create bed heater output on M307 H0 B0 S1.00 ; disable bang-bang mode for the bed heater and set PWM limit M140 H0 ; map heated bed to heater 0 M143 H0 S120 ; set temperature limit for heater 0 to 120C -;M307 H0 A303.1 C356.7 D1.4 S1.00 V24.0 B0 ; PID tune for "Bed" ;; HotEnd M308 S1 P"temp1" Y"thermistor" T100000 B4725 C7.060000e-8 A"Hotend" ; configure sensor 1 as thermistor on pin temp1 M950 H1 C"out2" T1 ; create nozzle heater output on out2 and map it to sensor 1 M307 H1 B0 S1.00 ; disable bang-bang mode for heater and set PWM limit M143 H1 S280 ; set temperature limit for heater 1 to 280C -;M307 H1 A751.5 C196.6 D4.7 S1.00 V23.9 B0 ; run PID tune for Hotend ; Fans M950 F0 C"out7" Q500 ; create fan 0 on pin out7 and set its frequency M106 P0 C"Hotend fan" S1 H1 T45 ; set fan 0 value. Thermostatic control is turned on -M950 F1 C"out4" Q500 ; create fan 1 on pin out4 +M950 F1 C"out4" Q10 ; create fan 1 on pin out4 M106 P1 C"Layer fan" S0 H-1 -L255 ; set fan 1 value. Thermostatic control is turned off ; Lights