16 lines
		
	
	
		
			578 B
		
	
	
	
		
			Plaintext
		
	
	
	
	
	
			
		
		
	
	
			16 lines
		
	
	
		
			578 B
		
	
	
	
		
			Plaintext
		
	
	
	
	
	
; 0:/macros/PID Tuning/PID Tune Hot End 250
 | 
						|
; Based on https://duet3d.dozuki.com/Wiki/Tuning_the_heater_temperature_control
 | 
						|
;
 | 
						|
 | 
						|
M291 S3 R"PID Tuning Hotend to 250c" P"Do not interrupt or leave unattended while tuning in progress."
 | 
						|
 | 
						|
M106 P0 S0.5		; set part fan to 50%
 | 
						|
M303 H1 S250 		; auto tune heater 1, default PWM, 250C target or maximum temperature
 | 
						|
 | 
						|
M98 P"0:/macros/Musical Tunes/TwoBits.g"
 | 
						|
 | 
						|
M291 S3 R"PID Tuning Complete" P"Check console for heater values. Values saved to config-Override.g"
 | 
						|
 | 
						|
M307 H1			; report values for heater 1
 | 
						|
M500			; Save values to config-override.g
 |