; 0:/macros/Calibration/E Steps Calibration.g
|
|
; Macro to calibrate the extruder steps per mm by extruding 110mm of filament slowly and comparing expected result with actual result.
|
|
|
|
M291 S3 R"Proceed?" P"Run E Steps per MM Calibration?"
|
|
M117 "Homing"
|
|
;G28 XY
|
|
G28 ;Z ; Home All Axis
|
|
M98 P"0:/macros/1_Nozzle Access.g" ; Move print head to nozzle access
|
|
T0 ; Activate Tool0
|
|
G10 P0 S220 R0 ; Hot end to 215c
|
|
M291 S3 R"Heating to 220" P"Mark 110mm on filament from top of extruder body."
|
|
M116 ; Wait for temp to 220
|
|
M291 R"Temp reached." P"Extruding 100mm at 1mm/s"
|
|
M83 ; relative extrusion
|
|
G1 E100 F60 ; Extrude 100mm of filament at 1mm/s
|
|
M400
|
|
G10 P0 S0 R0 ; Turn off hot end
|
|
T0 ; Deactivate Tool0
|
|
M291 S2 P"Measure distance to mark and update e steps."
|
|
M291 S2 P"old_e_steps * (100 / (110 - distance_to_mark))"
|
|
M291 S2 P"Repeat test to verify." R"E Steps calibration complete." |