; 0:/macros/PID Tuning/PID Tune Hot End 220
 | 
						|
; Based on https://duet3d.dozuki.com/Wiki/Tuning_the_heater_temperature_control
 | 
						|
;
 | 
						|
 | 
						|
M291 S3 R"PID Tuning Bed to 110c" P"Do not interrupt or leave unattended while tuning in progress."
 | 
						|
 | 
						|
M303 H0 S110 		; auto tune heater 0, default PWM, 60C target or maximum temperature
 | 
						|
 | 
						|
M98 P"0:/macros/Musical Tunes/TwoBits.g"
 | 
						|
 | 
						|
M291 S3 R"PID Tuning Complete" P"Check console for heater values. Values saved to config-Override.g"
 | 
						|
 | 
						|
M307 H1			; report values for heater 1
 | 
						|
M500			; Save values to config-override.g
 |